HEO Series
Pump: Belt drive triplex General pump with ceramic plungers · Thermal reliev valve · Factory preset trapping unloader
Motor: Open drip-proof electric motor with thermal overload protection
Frame: Powder coated steel side panels and frame · Removable panels for easy access to all internal components
Components: Control panel shown with on/off burner switch, on/off pump/motor switch and adjustable thermostat · Beckett burner with fuel/water separator ·1/2-inch schedule 80-coil with 5 pancake heat exchanger · High pressure outlet hose connection
Unit Includes: Quick connect nozzles (0°, 15°, 25° and 40°) · 50-foot x 3/8-inch steel wire-braided pressure hose with quick connects, swivel and bend restrictors · Professional-grade insulated trigger gun with safety lock-off · Adjustable pressure insulated dual lance with fixed detergent nozzle · 10-inch draft diverter
Miscellanous: Temperature rise 150°F above ambient, achieves 250°F/121°C outlet temperature with steam option · CAD cell relay with photo eye
Water Temperature | Hot |
Net Weight | 724.00 lbs. |
Shipping Weight | 844.00 lbs. |
Length | 56.50 in. |
Width | 29.00 in. |
Height | 49.75 in. |
Hour Meter HX-0106
Displays number of hours unit has been in operation
Time Delay Shutdown HX-0107
Timer will shut unit off automatically when trigger gun is released and timer reaches setting
Note: This option cannot be ordered with HX-0108 (1) Remote Station, you will need to order HX-0223 Time Delay Shutdown and First Remote instead
(1) Remote Station (Auto Start/Stop N/A) HX-0108
Adds control box which may be mounted away from unit to control on/off, burner and soap injection
Note: This option cannot be ordered with HX-0107 Time Delay Shutdown, you will need to order HX-0223 Time Delay Shutdown and First Remote instead
Additional Remotes (up to 3) HX-0110
Additional remotes that may be added to unit after the first remote is installed
Auto Start/Stop HX-0111
When trigger gun is released, the timer will turn unit off; when trigger gun is pulled unit will restart
K7 Unloader (Flow Sensitive) (Auto Start/Stop N/A) HX-0112
Converts pressure trapping unloader system to flow actuated K7 unloader. Pressure is not trapping in the discharge line when trigger is released.
Stainless-Steel Access Panels HX-0115
Converts powder coated painted access panels to stainless-steel material
Stainless-Steel Coil Wrap HX-0116
Converts powder coated painted coil wrap to stainless-steel material
Painted Box Kit HX-0117
Adds painted side and end panels
Painted and Stainless-Steel Box Kit HX-0118
Adds stainless-steel side panels and painted end panels
250°F Steam HX-0120
Steam option adjusts unloader valve counter-clockwise increasing outlet temperature to 250°F while lowering system pressure
Auto Start/Stop with First Remote HX-0124
When trigger gun is released timer will turn unit off, when trigger gun is pulled unit will restart; adds control box which may be mounted away from unit to control on/off, burner and soap injection
Elevated Float Tank, 4.0 GPM HX-0216
Float tank is located at the back of the unit
Elevated Float Tank, 5.0 GPM HX-0217
Float tank is located at the back of the unit
(2) 10-Gallon Fuel Tanks HX-0218
Adds 20-gallon fuel capacity to unit versus hose hook-up to fuel supply
Note: You must also order option HX-0216 or HX-0217 when ordering HX-0218
Time Delay With Remote HX-0223
Time Delay With Remote HX-0223